Specifications

DA7000 SERIES A.C. GENERATORS — OPERATION AND PARTS MANUAL — REV. #4 (08/07/09) — PAGE 19
17. Fuel drain Plug – Remove this plug to drain fuel from the
fuel tank.
18. Frame Ground Lug – Connect a ground strap between
this lug and a ground rod. Make sure that the ground rod is
inserted deep into the ground to provide a good earth
ground. Consult with local Electrical and Safety Codes for
proper connection.
19. Receptacle – Provides 120/240 volts output at 50 amps.
20. Receptacle – Provides 120/240 volts output at 30 amps.
21. Receptacle – Provides 120 volts output at 30 amps.
22. Receptacle G.F.C.I. – This receptacle provides 120 volts
output at 20 amps.
23. Circuit Protector Circuit Breaker – This single pole circuit
breaker provides circuit protection (250V @25 amps) for
the G.F.C.I receptacle.
24. Main Circuit Breaker – This 2-pole circuit breaker provides
circuit protection (265V @25 amps) for the Electric Parts
Assembly.
25. AC Voltmeter – Indicates the rated 60 Hz, single phase
output voltage.
29. Starter Switch – With key inserted turn clockwise to start
engine.
30. Oil Filter – Provides oil filtering for the engine
26. Hour Meter – Indicates number of hours machine has
been in use or hours engine was run.
27. Idle Control Switch – Regulates the engine speed when
the generator is under load.
28. Warning Lamp Display – Lights red when the following
conditions occur:
DA7000 SERIES GENERATORS — CONTROLS AND INDICATORS
Figure 4. DA7000SS/SSW Components (continued)
28A. Oil Pressure Lamp – If the oil pressure drops
suddenly, the oil pressure lamp will go on, and the
generator will shut down.
28B. Charge Lamp – The charge lamp will go on when
the battery fails to charge, and the generator will
shut down.
28C. Water Temperature Lamp – The water
temperature lamp will go on if the temperature
rises to an abnormally high level, and the
generator will shut down.