user manual
PAGE 22 — SP1E16A PAVEMENT SAW • OPERATION MANUAL — REV. #0 (04/14/10) 
MAINTENANCE/TROUBLESHOOTING (ELECTRIC MOTOR)
Chassis Lubrication
  Blade Shaft Bearings — Two zerk fittings are located 
at the lower-front area of the saw. Lubricate before daily 
use. Use a good quality automotive or general purpose 
grease. Check and lubricate more often if unit is under 
heavy  use.  Do  not  overfill  bearings.  Overfilling  can 
damage the grease seals  which can  result in bearing 
exposure  to  dirt  and  contaminants  which  can  then 
shorten the life of the bearings. Excess grease can also 
drip onto the cutting surface.
V-Belt
See  "V-belt  Alignment  and Tensioning"  section  in  this 
manual.
TROUBLESHOOTING
Table 4. Troubleshooting (Electric Motor)
Symptom Possible Cause Solution
Electric motor will not start.
Is there power?
Check power source. Check reset 
button.
Is power cable plugged in? Plug in power cable.
Is ON/OFF switch placed in ON 
position?
Place ON/OFF switch in ON position.
Defective cable? Check cable.
Electric motor continuously stops. Reset button OK? Check power source.
Electric motor RPM's too low. Low voltage? Check input voltage (230 VAC).
Electric motor RPM's too high. High voltage? Check input voltage (230 VAC).