User guide

AP6/AP8 SERIES TRASH PUMPS • OPERATION AND PARTS MANUAL — REV. #0 (06/11/14) — PAGE 41
PROGRAMMING GUIDE
Table 12. Programming Guide
Number Of
Pushes Of
OFF/SET
Button
Button To
Push
Parameters LED Multiplier
Factory
Setting
Range
Decrease
Value
Increase
Value
OFF/SET
Ignition Key
Turn On
System
4
1
8
2
0 OFF/SET
Preheat
Duration
4
8
2
1
OFF/SET
Input:
Time Seconds
12
84
4 0 Seconds 0~60 Seconds (-) MAN (+) AUTO
2 OFF/SET
Repeated
Starts
4
8
1
2
OFF/SET
Input: Number
Starts
4
8
1
2
1 3 0~15 (-) MAN (+) AUTO
4 OFF/SET
Pause
Between Starts
4
8
2 1
OFF/SET
Input:
Time Seconds
4
8
2 1
5 5 Seconds 5~75 Seconds (-) MAN (+) AUTO
6 OFF/SET Overcrank
8
2
4
1
OFF/SET
Input:
Time Seconds
8
2
4
1
2 10 Seconds 2~30 Seconds (-) MAN (+) AUTO
10 OFF/SET
Engine Cool-
Down Cycle
8
1
2
4
OFF/SET
Input:
Time Seconds
12
84
60 0 Seconds
0~900
Seconds
(-) MAN (+) AUTO
Reference Table 12 when programming of the MSS-200