Operation Manual

ROYAL evo
Seite 52
Alarm sequence:
x 10 seconds before the set alarm time: short beep
every second (È)
x When the alarm time is reached: long beep (È --- )
17.3. Timer ´ Sum“
I affects active model only
Range = 3 h 30 min
Press REV/CLR button in status display 3
(or in menu) to erase
This timer acts cumulatively, i.e. it sums the times. Once
started, it can be stopped again using the same switch,
then re-started by operating the switch once more.
Application:
Timing motor runs using throttle control as switch
You can set up the “Sum” timer to work in two different
modes:
1. Set alarm to 0:00:00
The timer begins at zero, runs forward (count-up),
adds the time and is stopped and re-started using
the assigned switch. You can reset it to zero in sta-
tus display 3 using the REV/CLR button, or in this
m e n u . I n t h i s c a s e t h e r e i s n o a l a r m .
2. Alarm not set to 0:00:00
The timer begins at the alarm time you set, runs
backward (count-down) and sounds the alarm
when the selected time has elapsed.
Alarm sequence:
x starting 5 min before the set alarm is reached:
short double beep every minute (ÈÈ)
x 5 seconds before the set alarm time:
short double beep every second (ÈÈ)
x When the alarm time is reached:
long double beep (È --- È ---)
17.4. Sub-menu ¶¶ Interval“
I affects active model only
Range = 3 h 30 min
Automatic erase at every re-start
With this timer you can call up the set interval as often
as you like.
The timer starts running at the set alarm time, runs
backward (count-down) and sounds the alarm when the
selected time has elapsed.
If the switch is at the ON position at the end of the alarm
time, the interval re-starts.
If the switch is at the OFF position at the end of the
alarm time, the timer continues to count up until the
maximum value is reached (4 h 30 min).
Alarm sequence:
x 1 second before the set alarm time:
short triple beep (ÈÈ È)
x When the alarm time is reached:
long triple beep (È --- È --- È)
18. Main menu „Memory“ I
The ROYALevo has 20 or 36 model memories, depend-
ing on the version you have purchased. The memory
spots are numbered continuously. You can also enter a
name with up to 16 characters for each model memory.
The model data is stored in an area of non-volatile me-
mory, and cannot be lost even if you disconnect the
transmitter battery from the transmitter.
In addition to memory management (switching, copy-
ing, erasing) you can also use this menu to create new
models (Î 18.6.) and manage the flight phases you set
up (Î 18.4.).
18.1. Sub-menu „Select model“
(change memory)
When you move to this sub-menu, the screen displays a
list showing all the model memories. The top of a typi-
cal list might look like this:
The active model memory is marked with the letter x.
An empty model memory is marked with --------.
Vacant memories can be managed, but not activated.
To change models simply select the memory you wish
to use, then press the 3-D digi-adjustor or the ENTER
button.
18.2. Sub-menu „Copy“
In this menu you can copy all the setup values relating
to the transmitter controls, mixers, servos, timers, model
name and trims.
The copy process is carried out in four stages:
1. Select the model which is to be copied.
This can be any model.
2. Confirm your selection with the 3-D digi-adjustor
or ENTER button. After the model name the letter
”c” (copy) appears.
3. Seek the destination
The model name and the “c” are carried along with
you during the search.
4. Confirm the destination with the 3-D digi-adjustor
or ENTER button.
x If the destination memory is empty, the copy
process is carried out immediately.
x If the destination memory already contains data,
you will see the security query:
“Overwrite existing model?
x At this point you can interrupt the copy process
by pressing the ENTER button or the 3-D digi-
adjustor.