Operation Manual
Manual
67
15.2. Menu Control
Control
Parameter Default
Aileron
Elevator
Rudder
Trim Current trim (display only)
Step Trim increment
0.5% 1.5% 2.5% 3.5%
D/R Dual-Rate
10% to 100%
Trvl Transmitter control travel setting
Flight phase specific
0% to 100%
Expo Flight phase specific
-100% 0% 100%
Collect.
(Collective
Pitch)
P1 to P5 5-point curve, flight phase specific
Throttle
Min. Throttle idle (I.C. engine)
0% 20% 100%
for electric 0%: recommended
P1 to P5 5-point curve, flight phase specific
Curve Switch throttle curve on / off
ON use throttle curve
OFF only a fixed value for electric
helicopters with regulated rotor
speed (Governor mode)
Limit Slow function for throttle limiter
0.0s to 6.0s
Additional
menu points
Spoiler
Flap
Speed Slow function
0.0s to 6.0s
Fixed values Flight phase specific
-100% OFF 100%
L. gear
Time Slow function
0.0s to 6.0s
Tow rel.
Brake
Gyro
Mixture
AUX1
AUX2
No adjustment at the transmitter control end!
Adjustment is only possible in the menu
¤Servo, Calibrate
Direction of rotation á
Centre P3
End-points P1, P5
Curve points P2, P4
Trigger
Point
(Î 15.3.)
15.3. Menu ¢TriggerPoint
In this menu you can set the switching thresholds for:
x the stick
symbol
‡,
(left or right stick, according to mode) and
x the two sliders E and F.
If a switching process is set up to operate with these
three transmitter controls, you can define a point
which determines when the switching is to take place:
Control
Parameter Default
‡
E
F
# ' Idle position of the transmitter
control; display only, not defined
during the assignment process:
# back, ' forward
- * Current switched state:
- OFF, * ON
Step Trigger point:
-100% 0% 100%
Example: switching a Timer at ¼ -throttle
Since the range extends from
-100% to 100%, the
switching point for ¼ -throttle must be set at
-50%.
Tip: using throttle / spoiler as switch
The sketch below clearly shows the connection bet-
ween the control position and the switching threshold.
For example, if the motor run time is to start at ¼ -
throttle, the threshold for the associated transmitter
control must be set to
-50%.
100% (max.)
0% (OFF)
50%
(½)
+100%
-100%
0%
(¾)
(¼)
15.4. Control menu screen layout
In our example we show the display for the transmitter
control
Aileron with all the available set-up parame-
ters. However, the screen may not look exactly like
this, depending on the transmitter controls you have
assigned, and the parameters associated with them:
The screen is divided into three areas:
1. Transmitter control names, active flight phase
At the top is the name of the transmitter control (in
our example
Aileron). Next to this is the name of
the active flight phase (in our example the flight
phase
NORMAL).
Control position Switching point