Operation Manual
ROYAL
pro
24
10.6. The Status displays
“Status display” is the term we use for the four differ-
ent screen displays which appear as options when the
transmitter is “started” (with or without RF trans-
mission).
You can switch between the individual Status displays
using the “” or “” buttons.
10.6.1. Status display
1 (standard)
1
2
3
4
5
6
Bars
Line 1 Status of the 3-D digi-adjusters.
Numerous set-up parameters can be allocated to
the 3-D digi-adjusters, which can then be adjusted
while the model is flying (Î 20.1.)
Line 2 Current model memory with memory number and
model name: 5:GLIDER
Line 3 Actual operating voltage of the transmitter battery in
numeric form and as a graphic bar display
Line 4
Transmitter type: ROYAL
pro
7, 9 or 12
Line 5 Owner’s name (Î 14.5.3.)
Line 6 Operating time for the currently active model mem-
ory (Î 18.2.)
Bars The four bars at the sides and bottom indicate the
current trim positions for the four primary control
functions / sticks
10.6.2. Status display
2 (flight phases)
1
2
3
4
5
Bars
Line 1 Status of the 3-D digi-adjusters (Î Status display 1)
Line 2 Current model memory (Î Status display 1)
Line 3 Actual battery voltage (Î Status display 1)
Line 4 Switch used to select the current flight phase (Î 19.4.)
Line 5
Current flight phase with number and name: 1:NORMAL
Bars Current trim positions (Î Status display 1)
10.6.3. Status display
3 (timers)
The screen only displays those timers to which a
switch has been assigned. After the timer the screen
shows the associated switch (in this example: the Slot
timer is controlled using switch “P”):
1
2
3
4
5
Bars
Line 1 Status of the 3-D digi-adjusters (Î Status display 1)
Line 2
Direction of operation of each timer (here: counting
down)
Line 3 Slot timer (Î 18.3.)
Line 4 Sum timer (Î 18.4.)
Line 5 Interval timer (Î 18.5.)
Bars Current trim positions (Î Status display 1)
10.6.4. Status display 4 (system information)
1
2
3
4
5
6
7
Line 1
Transmitter type: ROYAL
pro
7, 9 or 12
Software version: e.g. 2.53,
Loaded language set:
e.g. DE/EN (German / English)
Line 2
Channel number and frequency, or “No RF”
if no RF module is installed
Line 3
Modulation: FM/PPM 6 to 12 or FM/M-PCM
Line 4 Actual battery voltage
Line 5 Available battery charge quantity
Line 6 Calculated remaining transmitter operating time
based on the available battery charge quantity and
the actual current drain. Only displayed if an RF sig-
nal is being transmitted.
The red LED must flash!
Line 7
Transmitter operating time, up to 1000.0 hours,
then restarts at 0.0 h
ROYALpro12 2.53 DE/EN
CH:
066 35.060MHz
Modulation FM/PPM 9
Batt. voltage 7.81V
Battery charge 1699mAh
Remaining time 8.1h
Operating time 14.8h