Operation Manual

Operating Instructions
MULTIcont BL-15 brushless controller
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten • www.multiplex-rc.de Page 3/4
Anleitung MULTIcont BL-15 # 82 5959 (12-04-26/BRAN) • Errors and omissions excepted. •
MULTIPLEX
3.
Select direction of rotation
(triple beep, continuously repeated)
3.1
For reverse rotation
stick to full-throttle
position
OR:
For standard rotation*
stick to motor OFF
position
Confirmation signal
emitted
3.2
Stick to centre position
4.
Select motor cut-off type
(quadruple beep, continuously repeated)
4.1
For motor cut
(hard stop)
stick to full-
throttle position
OR:
For power
reduction *
stick to motor
OFF position
Confirmation signal emitted
LiPo batteries:
Motor off at 3.0 V / cell
NiXX batteries:
Motor off at 6.0 V!
LiPo batteries:
Motor speed is reduced at 3.2 V /
cell throttle stick to motor OFF
position open throttle motor off
completely at 2.9 V / cell
NiXX batteries:
Motor speed is reduced at 6.0 V
throttle stick to motor OFF position
open throttle motor off
completely at 5.8 V / cell
4.2
Stick to centre
position
5.
Select motor start-up behaviour
(five-times beep, continuously repeated)
5.1
For soft-start *
stick to full-throttle
position
OR:
For standard start-up
stick to motor OFF
position
Confirmation signal
emitted
Motor start-up time in
helicopter mode:
approx. 7.0 sec
in fixed-wing mode:
approx. 1.3 sec
Motor start-up time in
helicopter mode:
approx. 2.0 sec
in fixed-wing mode:
approx. 0.2 sec
5.2
Stick to centre position
6.
Select automatic timing
(six-times beep, continuously repeated)
6.1
For automatic timing ON*
stick in full-throttle
position
OR:
For automatic timing OFF
stick to motor OFF
position
Confirmation signal
emitted
6.2
Stick to centre position
7.
Select manual timing
only if automatic timing was previously set to OFF
(seven-times beep, continuously repeated)
7.1
For “hard” timing
(22 - 30 degrees)
stick to full-throttle
position
OR:
For “soft” timing (7 degrees)
stick to motor OFF
position
Confirmation signal
emitted
Recommended for
in-runners
Recommended for
out-runners
7.2
Stick to centre position
8.
Select pulse frequency
(eight-times beep, continuously repeated)
8.1
For 8 kHz pulse frequency
stick to full-throttle
position
OR:
For 16 kHz* pulse
frequency
stick to motor OFF
position
Confirmation signal
emitted
8.2
Stick to centre position
9.
Select model type
(nine-times beep, continuously repeated)
9.1
For helicopters (Governor
Mode)
stick to full-throttle
position
OR:
For fixed-wing models*
stick to motor OFF
position
Confirmation signal
emitted
Governor mode = constant
rotational speed maintained
In Governor mode the
Brake is automatically
switched OFF, even if you
previously selected Brake
On
10.
Quitting programming mode
10.1
Stick to centre position
Rising tone sequence
10.2
Stick to motor OFF position
Rising tone sequence
sounds twice: the controller
is ready for use, the altered
parameters have been
stored
* Default setting / as supplied
7. BEC = (BATTERY ELIMINATOR CIRCUIT)
MULTIcont BL-15 speed controllers are equipped with a BEC
system: the receiver and servos are fed power from the flight
battery via the regulator; no separate receiver battery is required.
Never connect a separate receiver battery!
Please note that the MULTIcont BL-15 speed controller’s BEC
power supply can only deliver a limited current to the receiving
system in the model:
The actual current drawn by a servo varies according to its
performance, the frequency of commands and in particular
the freedom of movement of the control surface linkages (!). This
means that it is essential to measure the current drain of the