Operation Manual

Menus
Page 134
PROFI TX
Example 1: 3-point 120º swashplate
Geometry
+120
Rotation
+0
Example 2: 4-point 90º swashplate
Geometry
-90
Rotation
+0
Rotation
Virtual swashplate rotation; the parameter is required in the following cases:
o The swashplate is physically installed in the model in such a way
that the MAINROTOR-FB servo is not located on the centreline.
o The model rolls (aileron movement) when an elevator control
command is given, and vice versa.
Flight direction
MAINROTOR-4
90
MAINROTOR-R.
MAINROTOR-L.
MAINROTOR-FB
Flight direction
MAINROTOR-FB
120
MAINROTOR-R.
MAINROTOR-L.