Operation Manual
Operating Instructions
Power Peak
®
Twin EQ-BID
16
Parameter NiCd NiMH LiPo LiFe LiIo Lead
Cell count/
Battery voltage
1 - 18 cells 1 - 18 cells
1 S (3,7 V) -
7 S (25,9 V)
1 S (3,3 V) -
7 S (23,1 V)
1 S (3,6 V) -
7 S (25,2 V)
1 cell...12 cell
(2-24 V)
Capacity 0,1 - 9,9 Ah 0,1 - 9,9 Ah 0,1 - 50 Ah 0,1 - 50 Ah 0,1 - 50 Ah 0,1 - 65 Ah
Charge current 0,1 - 20 A 0,1 - 20 A 0,1 - 20 A 0,1 - 20 A 0,1 - 20 A 0,1 - 20 A
Discharge current 0,1 - 10 A 0,1 - 10 A 0,1 - 10 A 0,1 - 10 A 0,1 - 10 A 0,1 - 10 A
Discharge voltage 0,1-1,1 V/cell 0,1-1,1 V/cell 2,5-3,9 V/ cell 2,5-3,3 V/ cell 2,5-3,6 V/ cell fixed 1,8 V/ cell
Peak sensitivity. 5-25 mV/cell
3-15 mV/cell
or. ZERO peak
----
Cut-off
Temperature
10 - 65
O
C in
1
O
C steps
10 - 65
O
C in
1
O
C steps
10 - 65
O
C in
1
O
C steps
10 - 65
O
C in
1
O
C steps
10 - 65
O
C in
1
O
C steps
10 - 65
O
C in
1
O
C steps
Maximum capacity
10 - 150 % in
10 % steps
10 - 150 % in
10 % steps
10 - 120 % in
10 % steps
10 - 120 % in
10 % steps
10 - 120 % in
10 % steps
10 - 120 % in
10 % steps
TCS capacity - - 10 - 100% 10 - 100% 10 - 100% -
TCS End action - - Continuous/stop
Continuous/
stop
Continuous/stop -
Time limit
20 - 300 min.
/ off
20 - 300 min.
/ off
20 - 300 min.
/ off
20 - 300 min.
/ off
20 - 300 min.
/ off
20 - 300 min.
/ off
Charge rate - - 1-5 1-5 1-5 -
Cycle 1-10 1-10
Storage pro-
gramme
Storage pro-
gramme
Storage pro-
gramme
-
Pre-Peak-reduction
1 - 20 Min. in
minute steps
1 - 20 Min. in
minute steps
----
Trickle charge
0 - 500 mA in
50 mA steps.
0 - 500 mA in
50 mA steps.
----
Trickle charge with
BID
C/20 C/20 - - - -
# 30 8563
50