Operation Manual
3. TECHNICAL SPECIFICATION
Operating voltage: 11 V...28 V DC, (12 V as well as 24 V lead battery or a powerful
mains power supply. do not use a car battery charger!
Cell count: Output1:
1-18 cells NC / NiMH
1-7 cells LiFe, LiIo, LiPo
1-12 cells Pb / lead
Output 2:
1-18 cells NC / NiMH
1-7 cells LiFe, LiIo, LiPo
1-12 cells Pb / lead
OUTPUT OUT 1 and. 2:
Charging current: 0.1 ... 20 A (max. 500 Watt at 24 V; max. 250 W with 13,5 V pro
Output)
Discharging current: 0.1 ... 10 A (max. 50 Watt per output)
Equalizer connection: for 1-7 cells LiFe, Lilo, LiPo
Discharge voltage.: 0,1 ... 1,1 V per cell (NiCad- / NiMH-batteries)
2,5 ... 3,7 V per cell (LiPo- batteries), 2,5...3,6 V (LiIo), 2,5...3,3
V (LiFe)
1,8 V per cell (lead batteries)
Trickle charge : 0 ... 500 mA, adjustable in 50 mA steps for NC- / NiMH-
batteries, C/20 with BID Chip
Equaliser current: approx. 300 mA
Charge Cut-Off:
NC/NiMH: automatic, digital Delta-Peak system
Cut-off sensitivity: 5 ... 25 mV per cell NC-batteries
3 ... 15 mV per cell NiMH- batteries or ZERO peak
Lead and lithium: automatic, voltage-dependent, CC-CV method
(LiPo 4.2 V, LiIo 4.1 V, LiFe 3.7 V, lead batteries 2.3 V/ cell)
Temperature cut-off: 10 ... 65°C, adjustable in 1°C steps
Capacity monitoring: 10 ... 150 %, adjustable in 10 % steps (NC- / NiMH- batteries)
10 ... 120 %, adjustable in 10 % steps (Lithium- / lead batteries)
Time limit: 20-300 Min. / Off
TCS (Terminal Capacity
Selection) capacity cut-off/ end warning with 10- 100% charge condition of the Lithium
battery
Dimensions: 170 x 175 x 60 mm
Weight: approx. 1220 g