Operation Manual

Alternatively, the battery voltage can be selected in
2V-steps per cell for lead battery packs.
The following voltages are available to use for lithium batteries:
ENTERING THE BATTERY CAPACITY
In this menu, battery capacity can be selected in
steps of 100 mAh (PB, 500 mAh). The battery capa-
city setting for lithium battery packs mainly serves
as the basis for the 1C charge, i.e. the charging current is automatically set to the corres-
ponding 1C charge of the battery. It additionally serves as a battery safety function.
The range of capacities shown in the
table here are available and depend
upon the type of battery:
SETTING THE CHARGING CURRENT
The charging current up to 10A can be selected in
steps of 0.1 A. The maximum charging current is
dependent on the number of cells or the battery vol-
tage and the maximum charging capacity (max. 2C
for lithium batteries). The processor in the battery
charger limits the maximum charging current if the maximum charging capacity is excee-
ded.
Operating instructions
POWER PEAKĀ® TRIPLE 360 W EQ-BID
14
Cell count Battery voltage
1 2 Volt
2 4 Volt
3 6 Volt
4 8 Volt
5 10 Volt
6 12 Volt
Battery type Battery capacity
NiCd 100 - 9900 mAh
NiMH 100 - 9900 mAh
LiPo 100 - 9900 mAh
LiIo 100 - 9900 mAh
LiFe 100 - 9900 mAh
Pb (lead) 0.50 Ah - 20.00 Ah
# 30 8562