Operation Manual

t 5IF45"35CVUUPOJTQSFTTFEUPTUBSUUIFTFMFDUFEPQFSBUJPOFH$)"3(&
t "GUFSDPOOFDUJOHUPUIFTVQQMZWPMUBHFUIJTCVUUPOJTVTFEUPTFMFDU
"manual mode" (MANUAL).
t 5IFh*/$hCVUUPOJTBMTPVTFEUPTFMFDUUIFSFRVJSFEMBOHVBHFTFFDIBQUFS
STOP / ENTER BUTTON
t "DVSSFOUPQFSBUJPOFH$)"3(&DBOCFUFSNJOBUFECZQSFTTJOHUIF4501CVUUPO
t 5IF&/5&3CVUUPODPOGJSNTBTFMFDUJPOFHBDUJWBUJPOPSEFBDUJWBUJPOPGBTFMFDUFE
menu.
All buttons have an Autorepeat function so that the respective function is repeated-
ly switched when the button is held pressed.
4. Technical specification (details refer to each charge output)
Operating voltage: 4.8 - 6 V
(Do not use as a car battery charger!)
Cell count: 1 ... 14 cells NC/NiMH,
1 ... 6 cells LiIo (3.6 V), LiPo (3.7 V), LiFe (3.3 V)
1 ... 6 cells (2...12 V) lead-acid battery
Charging current: 0.1 ... 10 A at max. 120 W
Discharging current: 0.1 ... 1 A at max. 5 W
Equalizing current: max. 300 mA
Charging power: 120 W, current is controlled to suit
e.g. 28 V battery voltage, charging current approx. 4.2 A
Discharging power: 5 W, current is controlled to suit
Trickle charge: Charged capacity <1 Ah: No trickle charge
$IBSHFEDBQBDJUZ"I5SJDLMFDIBSHFBU$
(only with NC and NiMH)
Cut-off voltage: 0.8 V per cell for NC and NiMH,
3.0 V per cell for LiPo, Lilo
2.5 V per cell for LiFe
1.8 V per cell for lead batteries
Charge Cut-Off:
NC/NiMH: automatic, digital Delta-Peak system
Lead and lithium: automatic, voltage-dependent, CC-CV method
Dimensions: est. 270 x 195 x 50 mm
Functions: Charge, discharge, discharge-charge, balance
10 internal memory locations
Operating instructions
POWER PEAK® TRIPLE 360 W EQ-BID
7
# 30 8562
31