Operation Manual

Alternatively, for lead-acid batteries you can select
a battery voltage in increments of 2 V per cell using
the ‘INC’ or ‘DEC’ button. Press the ‘ENTER’ button
again to confirm your selection.
The following voltages are available to
use for lithium batteries:
ENTERING THE BATTERY CAPACITY
Press the ‘INC/ DEC ’ button to leaf through the
screen display until the arrow is next to Battery
Capacity. Press the ‘ENTER’ button and the ‘+ / -’
symbol flashes. The battery capacity can be selec-
ted in steps of 100 mAh (PB, 500 mAh). The battery capacity setting for lithium battery
packs mainly serves as the basis for the 1C charge, i.e. the charging current is auto-
matically set to the corresponding 1C
charge of the battery. It additionally
serves as a battery safety function.
Press the ‘ENTER’ button again to
confirm your selection. The range of
capacities shown in the table here are
available and depend upon the type of
battery:
SETTING THE CHARGING CURRENT
Press the ‘INC/ DEC ’ button to leaf through the screen display until the arrow is next to
End. Press the ‘ENTER’ button and the ‘+ / -’ sym-
bol flashes. The charging current can be selected
in steps of 0.1 A. Press the ‘ENTER’ button again
to confirm your selection. The charging current up
to 5A can be selected in steps of 0.1 A. The maximum charging current is dependent on
the number of cells or the battery voltage and the maximum charging capacity (max. 2C
for lithium batteries). The processor in the battery charger limits the maximum charging
current if the maximum charging capacity is exceeded.
Operating Instructions
Power Peak® Quad EQ-BID 230 V
14
Cell count Battery voltage
1 2 Volt
2 4 Volt
3 6 Volt
4 8 Volt
5 10 Volt
6 12 Volt
Battery type Battery capacity
NiCd 100 - 9900 mAh
NiMH 100 - 9900 mAh
LiPo 100 - 9900 mAh
LiIo 100 - 9900 mAh
LiFe 100 - 9900 mAh
Pb (lead) 0,50 Ah - 20,00 Ah
# 30 8196