Operation Manual
SELECTING A MEMORY LOCATION
Press the ‘INC’ button to leaf through the screen
display until the arrow indicates Memory. Press the
‘ENTER’ button and the ‘+ / -’ symbol flashes. You
can now select a memory within the range 0 to 9
using the ‘INC’ or ‘DEC’ button. Press the ‘ENTER’
button again to confirm your selection.
SELECTING THE TYPE OF BATTERY
Press the ‘INC/ DEC ’ button to leaf through the
screen display until the arrow is next to Battery
Type. Press the ‘ENTER’ button and the ‘+ / -’ sym-
bol flashes. You can now select a battery type from NiCd, NiMH, LiPo, LiIo, LiFe or Pb
(lead-acid) using the ‘INC’ or ‘DEC’ buttons. Press the ‘ENTER’ button again to confirm
your selection.
SETTING UP NUMBER OF CELLS/BATTERY
VOLTAGE
Press the ‘INC/ DEC ’ button to leaf through the
screen display until the arrow is next to Cell Count. Press the ‘ENTER’ button and the ‘+
/ -’ symbol flashes. Now the number of cells can be selected between 1 and 14 cells for
NC and NiMH battery packs using the "INC/DEC" buttons. Press the ‘ENTER’ button again
to confirm your selection. With the battery types LiPo, LiIo, LiFe and Pb (lead-acid) you
should enter the nominal battery voltage instead of the cell count.
Example: Press the ‘INC/ - ’ button to leaf through the screen display until the arrow indi-
cates Battery Voltage. Press the ‘ENTER’ button
and the ‘+ / -’ symbol flashes. For a LiPo battery,
the battery voltage can now be selected in 3.7 V per
cell increments. Press the ‘ENTER’ button again to
confirm your selection.
The following voltages are available to use for lithi-
um batteries:
LiPo LiIo LiFe
Operating Instructions
Power Peak® Quad EQ-BID 230 V
13
Cell count Battery voltage
1 3,7 Volt
2 7.4 Volt
3 11.1 Volt
4 14,8 Volt
5 18,5 Volt
6 22,2 Volt
Cell count Battery voltage
1 3,6 Volt
2 7,2 Volt
3 10,8 Volt
4 14,4 Volt
5 18,0 Volt
6 21,6 Volt
Cell count Battery voltage
1 3,3 Volt
2 6.6 Volt
3 9,9 Volt
4 13,2 Volt
5 16,5 Volt
6 19.8 Volt
# 30 8196