4. TECHNICAL SPECIFICATION
Operating Voltage: 230 V AC/ 50 Hz
Cell count: 1 ... 14 cells NC/NiMH,
1 ... 6 cells LiIo (3.6 V), LiPo (3.7 V), LiFe (3.3 V)
1 ... 6 cells (2...12 V) lead-acid battery
Charging current: 0.1 ... 5 A at max. 50 W
Discharging current: 0.1 ... 1 A at max. 5 W
Equalizing current: max. 250 mA
Charging power: 50 W, current is controlled to suit
e.g. 24 V battery voltage, charging current approx. 2.0 A
e.g. 28 V battery voltage, charging current approx. 1.7 A
Discharging power: 5 W, current is controlled to suit
Trickle charge: Charged capacity <1 Ah: No trickle charge
$IBSHFEDBQBDJUZ"I5SJDLMFDIBSHFBU$
(only with NC and NiMH)
Cut-off voltage: 0.8 V per cell for NC and NiMH,
3.0 V per cell for LiPo, Lilo
2.5 V per cell for LiFe
1.8 V per cell for lead batteries
Charge Cut-Off:
NC/NiMH: automatic, digital Delta-Peak system
Lead and lithium: automatic, voltage-dependent, CC-CV method
Dimensions: est. 225 x 170 x 40 mm
Functions: Charge, discharge, discharge-charge, balance
10 internal memory locations
Note:stated values refer to a single charge output port!