Procedure
Display
1.
Select the SERVO1 (e.g. for servo 1) setting in the
SERVO menu and switch to the second line
2.
Set the direction of rotation and signal format e.g.
MPX, reversed
3.
Return to the first line.
Continue as shown in the flow chart.
8.3.2. Adjusting the servo centre and end-points
You can adjust the centre position and end-points (both directions separately) for
all seven channels individually.
The purpose of adjusting the centre point is to ensure that the control surface is at
centre when the transmitter control and its associated trim are at neutral. The end-
point adjustments can be used to adjust the control surface travels in both direc-
tions to the exact values recommended by the model manufacturer.
You select the value which is to be adjusted by moving the associated stick in the
direction you wish to alter; a symbol then appears on the screen as follows:
Symbol Meaning
Servo end-point for transmitter control, right or forward
Servo centre
Servo end-point for transmitter control, left or back
This is how you set centre and end points (travel) for the servos:
Procedure Display
1.
Select the SERVO1 setting (e.g. for servo 1) in the
SERVO menu and switch to the second line
2.
Move the associated transmitter control to centre
3.
The centre point can now be adjusted e.g. -6%
Adjusting the servo end-points:
4.
Move the associated transmitter control to one of
the end-points and hold it there
or
5.
The selected end-point can now be adjusted,
e.g. 96%
To adjust the other servo end-point first move the transmitter control to the oppo-
site extreme and repeat steps 4. - 5.
6.
Return to the first line