Operation Manual Lipo Saver
17
Once you have completed all the steps as
described in the Installation section, the
LiPo SAVER 2…6S is ready for use with the basic
default settings.
· First switch your transmitter on.
· The balancer plug attached to your battery must rst
be connected to the balancer socket.
· Connect the ight battery to your speed controller.
· The LiPo SAVER initially checks the state of the indi-
vidual battery cells, and generates a percentage at
Address 2 reecting the battery’s state of charge. If
the battery you connect is at less than 80% of a full
charge, the sensor generates a telemetry warning.
· After a few seconds - or (-60A version) after
measuring a current rise caused by the motor
starting up, the sensor displays the lowest of the
individual battery cell voltages.
The LiPo monitor is now active:
· If any individual cell voltage falls below the user-
variable early warning threshold, the sensor
generates a telemetry warning.
· If the battery voltage falls to the absolute low-voltage
threshold (variable according to battery type - default
setting: LiPo - 3.1 Volt), then the sensor generates a
telemetry warning. To help you differentiate between
the warnings, the absolute warning is displayed with
a minus (“-”) prex.
· The LiPo SAVER 2...6S 60A version also displays the
current owing at Address 3, and battery capacity
already consumed at Address 4.
Important note!
After each ight you must always disconnect the LiPo
SAVER completely from the battery: rst disconnect the
battery from the speed controller, then withdraw the
balancer plug from the LiPo SAVER.
3. Using the sensor for the rst time
4. Default settings
The LiPo SAVER 2...6S is set up by default to the
following settings:
Individual cell voltage address 2
Alarm after start-up at cell voltage < 80%
Overall voltage address off
Battery type LiPo
Early warning threshold 3,40 V
Current address (external) off
If you wish to change any of these conguration
settings, it will be necessary to re-congure the
sensor.
In this case please continue with the section
entitled “Conguration”.
The additional settings of the
LiPo SAVER 2...6S - 60A are as follows:
Actual current address 3
Maximum current alarm off
Maximum current address off
Capacity / residual capacity address 4
Battery capacity 0 mAh
Capacity / residual capacity alarm off
Capacity display in % / mAh mAh
Early warning threshold 3,30 Volt