Cut Sheet

18
1-800-HOUWIRE
www.houwire.com
2013 Aluminum Catalog. All data subject to change without notice.
Secondary
Underground
Distribution
ALUMINUM WIRE & CABLE
Aluminum URD
Single Conductor 600V Secondary URD
8 (7)
6 (7)
4 (7)
2 (7)
1 (19)
1/0 (19)
2/0 (19)
3/0 (19)
4/0 (19)
250 (37)
300 (37)
350 (37)
400 (37)
450 (37)
500 (37)
600 (61)
700 (61)
750 (61)
1000 (61)
0.06
0.06
0.06
0.06
0.08
0.08
0.08
0.08
0.08
0.095
0.095
0.095
0.095
0.095
0.095
0.11
0.11
0.11
0.11
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
0.26
0.3
0.35
0.41
0.49
0.52
0.57
0.62
0.68
0.75
0.81
0.85
0.9
0.94
0.98
1.09
1.16
1.19
1.34
6.6
7.6
8.9
10.4
12.4
13.2
14.5
15.7
17.3
19.1
20.6
21.6
22.9
23.9
24.9
27.7
29.5
30.2
34
34
47
67
97
128
154
186
225
274
329
385
439
493
547
601
725
830
883
1144
51
70
100
144
190
229
277
335
408
490
573
653
734
814
894
1079
1235
1314
1702
40
46
63
86
98
115
132
150
173
196
224
242
259
---
299
328
362
368
431
44
56
72
100
111
133
150
172
200
228
255
278
300
---
344
377
416
427
494
49
59
81
108
124
146
162
189
221
248
281
302
329
---
378
416
459
470
540
74
96
117
154
171
193
221
253
290
317
349
381
410
439
464
514
549
567
665
36
47
60
82
97
112
132
155
185
199
223
248
272
295
318
355
386
403
492
Inches mm Inches mm lb / kft. kg/km 60°C 75°C 90°C
Direct
Buried2
Pole Riser
Conduit3
Insulation Thickness Nominal Diameter Approx. Net Weight Ampacity NEC1 Ampacity ICEA*
Cornell
Princeton
Mercer
Clemson
Kenyon
Harvard
Yale
Tufts
Beloit
Hofstra
Gonzaga
Rutgers
Dartmouth
Brown
Emory
Duke
Furman
Sewanee
Fordham
600V SECONDARY URD
Concentric Lay
Aluminum 1350 Conductors
Code
Name
Size
Stranding
* Ampacity based on 40˚C ambient temperature, crosswind at 2ft/s, and no sun.
- All drawings, designs, specications, plans and particulars of weights, sizes and dimensions contained in the technical or commercial documentation of Houston
Wire & Cable Company is indicative only and shall not be binding on Houston Wire & Cable Company or be treated as constituting a representation on the part of
Houston Wire & Cable Company. All data subject to change without notice.
APPLICATION:
The cable is rated at 600V for underground secondary
distribution not exceeding 90˚C. It may be directly buried in
earth or installed in duct in both wet or dry locations.
CONSTRUCTION:
Conductors: Class B compressed concentric lay stranded
1350 aluminum alloy per ASTM B231 or AA-8000 aluminum
alloy per ASTM B800 & B801.
Insulation: Phase conductors in black thermoset cross-linked
polyethylene (XLPE). Neutral conductor in black thermoset
cross-linked polyethylene (XLPE) identied by yellow striping
or full yellow jacket.
PRODUCT FEATURES:
Individual cables are UL Listed as USE-2
RUS accepted
Temperature rating of 90˚C dry, wet, and direct burial
Heat, ozone, oil, and chemical resistant
Tear and abrasion resistant
CONFIGURATION:
Black phase insulated conductors cabled with neutral.
Neutral will be marked with yellow striping or yellow jacket.
ADDITIONAL STANDARDS:
ICEA S-105-692: 600V Single layer thermoset insulated
utility underground distribution cable
UL854: Service Entrance Cables
RUS accepted
Aluminum Conductor XLPE