Cut Sheet
Product Codes, Trade Sizes, Conductors, Packaging & Weights
Grounding Approx. Armor
Product Code Conductor Length (feet) Weight/1000 Minimum
Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)
Stock Items
2804G42-00 2804G60-00 12-2 Solid 12 250' 1000' 130 0.489
2805G42-00 2805G60-00 12-3 Solid 12 250' 1000' 155 0.520
2806G42-00 2806G60-00 12-4 Solid 12 250' 1000' 185 0.545
2858G42-00 2858G60-00 12-2 Stranded 12 250' 1000' 130 0.489
2859G42-00 2859G60-00 12-3 Stranded 12 250' 1000' 155 0.520
2860G42-00 2860G60-00 12-4 Stranded 12 250' 1000' 185 0.545
2807G32-00 — 10-2 Solid 10 125' — 180 0.500
2808G32-00 — 10-3 Solid 10 125' — 225 0.541
2809G32-00 — 10-4 Solid 10 125' — 275 0.587
2807G42-00 2807G60-00 10-2 Solid 10 250' 1000' 180 0.500
2808G42-00 2808G60-00 10-3 Solid 10 250' 1000' 225 0.541
2809G42-00 2809G60-00 10-4 Solid 10 250' 1000' 275 0.587
Specialty Colors
2804G42-04 2804G60-04 12-2 Solid (red, white) 12 250' 1000' 130 0.489
2804G42-05 2804G60-05 12-2 Solid (blue, white) 12 250' 1000' 130 0.489
2805G42-04 2805G60-04 12-3 Solid (red, blue, white) 12 250' 1000' 155 0.520
2805G42-05 2805G60-05 12-3 Solid (black, blue, white) 12 250' 1000' 155 0.520
AC
28
AFC Cable Systems
800-757-6996 www.afcweb.com
HCF-Lite
®
Aluminum Healthcare Facilities Cable
(120V) Cable Technical Specifications
NOTE: All dimensions and weights are subject to normal manufacturing tolerances.
Not to be used with set screw type fittings or on DC circuits.
Sizes 14 AWG, 8 AWG, & larger available by special order and subject to lead time and minimum quantities.
WARNING: DO NOT RE-IDENTIFY CONDUCTOR COLORS.
A
luminum Interlocked Armor
(Color-Coded Green)
Nylon Thermoplastic
THHN Insulation
Insulated
Bushing
Bare Aluminum
Bonding Strip
Paper Wrap on
Each Conductor
Insulated
Copper
Ground
Copper
Conductors
Specification Description
Specification HCF-Lite ColorSpec ID System
®
Armor Aluminum Interlocking Strip
(green striped)
Conductors Solid/Stranded Copper (see below)
Conductor Insulation THHN
Conductor
Insulation Paper Wrap
Covering
Maximum
Temperature 90°C (dry)
Rating
Grounding 16AWG integral Bond
Wire/Armor combination
plus insulated green
grounding conductor
(2 grounding means)
Neutral Conductor White
Maximum 600V
References & Ratings
• U.L. 4, 83, 1479, 1581,
File Reference E7330
• NEC 250.118, 300.22(C),
392, 320, 517.13, 518, 645
• Federal Specification A-A-59544
(formerly J-C-30B)
• Meets all applicable OSHA
and HUD Requirements
• Cable Tray installations per NEC
• U.L. Classified 1, 2 and 3-hour
Through-Penetration Fire Wall
File R-14929
• Environmental Air-Handling
Space installation
See page 38 for bond wire termination details.
Additional black stripe
denotes 2 conductor cable
Additional black and red stripe
denotes 3 conductor cable
Additional black, red and light blue
stripes denote 4 conductor cable
Additional red and white stripes
denote special 2 conductor cable
Additional light blue and white stripes
denote special 2 conductor cable
Additional red, light blue and white
stripes denote special 3 conductor cable
Additional black, light blue and white
stripes denote special 3 conductor cable
AFC’s ColorSpec ID System
®
Emergency circuits require special consideration in healthcare settings.
Review NEC 517.30 (C)(3)(3) for guidance on the use of HCF cables on emergency circuits.
AFC0704_Cbl Cat Body 4/10/07 10:20 AM Page 28