Cut Sheet

Product Codes, Trade Sizes, Conductors, Packaging & Weights
Grounding Approx. Armor
Product Code Conductor Length (feet) Weight/1000 Minimum
Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)
Stock Items
1504G42-00 1504G60-00 12-2 Solid 12 250' 1000' 220 0.489
1505G42-00 1505G60-00 12-3 Solid 12 250' 1000' 260 0.520
1506G42-00 1506G60-00 12-4 Solid 12 250' 1000' 300 0.545
1507G32-00 1507G60-00 10-2 Solid 10 125' 1000' 290 0.500
1508G32-00 1508G60-00 10-3 Solid 10 125' 1000' 345 0.541
1509G32-00 1509G60-00 10-4 Solid 10 125' 1000' 405 0.587
1507G42-00
10-2 Solid 10 250'
290 0.500
1508G42-00
10-3 Solid 10 250'
345 0.541
1509G42-00
10-4 Solid 10 250'
405 0.587
Specialty Colors
1504G42-04 1504G60-04 12-2 Solid (red, white) 12 250' 1000' 220 0.489
1504G42-05 1504G60-05 12-2 Solid (blue, white) 12 250' 1000' 220 0.489
AC
26
AFC Cable Systems
800-757-6996 www.afcweb.com
HCF-90
®
Steel Healthcare Facilities Cable
(120V) Cable Technical Specifications
NOTE: All dimensions and weights are subject to normal manufacturing tolerances.
Sizes 14 AWG, 8 AWG, & larger available by special order and subject to lead time and minimum quantities.
WARNING: DO NOT RE-IDENTIFY CONDUCTOR COLORS.
Emergency circuits require special consideration in healthcare settings.
Review NEC 517.30 (C)(3)(3) for guidance on the use of HCF cables on emergency circuits.
Additional black stripe denotes
2 conductor cable
Additional black, and red stripe denotes
3 conductor cable
Additional black, red and light blue
stripes denote 4 conductor cable
Additional red and white stripes denote
special 2 conductor cable
Additional light blue and white stripes
denote special 2 conductor cable
Galvanized Steel Armor
(Color-Coded Green)
Nylon Thermoplastic
THHN Insulation
Insulated
Bushing
Bare Aluminum
Bonding Strip
Insulated
Copper
Ground
Paper Wrap on
Each Conductor
Copper
Conductors
Specification Description
Specication HCF-90 ColorSpec ID System
®
Armor Galvanized Interlocking Steel Strip
(green striped)
Conductors Solid Copper
Conductor THHN
Insulation
Conductor
Insulation Paper Wrap
Covering
Maximum
Temperature 90°C (dry)
Rating
Grounding 16AWG integral
Bond Wire/Armor
combination plus insulated
green grounding conductor
(2 grounding means)
Neutral Conductor White
Maximum 600V
Voltage Rating
References & Ratings
U.L. 4, 83, 1479, 1581,
File Reference E7330
NEC 250.118, 300.22(C), 392,
320, 517.13, 518, 645
Federal Specification A-A-59544
(formerly J-C-30B)
Meets all applicable OSHA
and HUD Requirements
Cable Tray installations per NEC
U.L. Classified 1, 2 and 3-hour
Through-Penetration Fire Wall
File R-14929
Environmental Air-Handling
Space installation
AFC’s ColorSpec ID System
®
See page 38 for bond wire termination details.