Specifications

3.2 T
.
.
.
.
orch Operating Principle
Once the torch is filled with the proper fluid, the power supply is connected, and voltage
is applied to the cathode (the ON button is pressed), the operator can cause the torch to
produce an arc by pressing the start button briefly This results in the cathode shorting to
the torch nozzle As the start button is released, an electric arc is produced between the
cathode and nozzle Arc energy heats the nozzle, which in turn heats the evaporator,
which causes the fluid to heat and turn into steam Steam flows toward the nozzle outlet
Escaping from the nozzle, steam compresses the
electric arc Arc compression increases arc temperature Compressed electric arc heats
the steam to ionization temperature
under internal pressure . - . bar
The system has two modes of operation
MODE I is the indirect arc mode An electric arc is produced between cathode and
nozzle The plasma jet is the only vehicle that transfers energy to the workpiece
material
MODE II is the direct arc mode The conductive workpiece is part of the cutting (welding)
circuit and the electric arc is produced between the workpiece and the cathode inside
the plasma jet This causes a significant increase in the amount of thermal energy
transferred to the workpiece
assembly (see
Section 6.6.2) ethanol mixture
in accordance to
(0 4 1 2 ).
..
.
.
.
.
.
.
,
.
.
The device includes two torches, which are structurally identical. One with a green label
is initially equipped for cutting and the torch with the red label for welding. These torches
are interchangeable by changing the nozzle, by adjusting the cathode
, and by replacing the working liquid (water or water/ ). We
recommend using each torch its respective color-coded labels.
33 P
.
.
.
. . ower Supply
Inverter power supply with forced air cooling acts as a current conditioner and has a
steeply sloping output characteristic Reliable current conditioning for plasma torch
electrical arc is performed for a wide range of output voltages applied to the torch
The top of the unit is equipped with a carrying handle
A . mm ( ) is used to connect the power
supply to outside power grounding wire is green-yellow in color
3х25
().
2
power cable minimum No. 14/3 AWG
7.1 .6 Repair, Service, and Support
Repair and maintenance are performed by authorized dealers.
3
34
7
15