Operation and Maintenance Manual

MultiHaul™ Installation, Operation and Maintenance Manual
Page 83
system time : 12:34:15
system cli-timeout : 15
system loop-permission : enabled
system terminal-units-isolation : disable
system eth-ports-isolation : disable
system unit-mode : normal
system leds-turn-off : never
system phy-buffer-scheduler : default
This section allows monitoring and configuring the following parameters:
System Description (R/O) Product model.
SNMPID Siklus SNMP ID
System Uptime R/O field. Time elapsed from last power on.
Contact user configurable info (default blank).
Name Unique name for each system.
Location user configurable info (default blank ).
Voltage R/O field. Input voltage and indication of PoE input.
Temperature R/O field. System temperature in Degrees C.
Date Date [YYYY.MM.DD]
Time Time [HH:MM:SS]
CLI Timeout auto-logout CLI timeout
Loop Permission system loopback permission
Terminal units Isolation [BU only] when enabled, packets coming from one TU
and received by BU will not be transmitted to any other TU, isolation the traffic
of each TU from neighboring TUs.
Eth Ports Isolation [BU and TU with 3 ports] when enabled, packets coming
from one port of the radio will not be transmitted to any other ports of the TU
(only towards the radio ports and the management host), isolation the traffic of
each Eth port from other Eth ports.
Unit Mode Normal or Low-Power. Use Low-Power for bench testing only, when
distance between radios is up to few meters.
Remote Config (Terminal Unit only) when enabled, TU will obtain its
configuration from the BU (refer to TU Auto-Provisioning feature).
Leds Turn Off Time when value entered (in minutes), the radio Leds will turn
off automatically after the set time (up to 6000 minutes). To turn on the Leds,
reboot the radio. If left blank, Leds will not turn off automatically (default).