Operation and Maintenance Manual
MultiHaul™ Installation, Operation and Maintenance Manual
Page 80
remote-terminal-unit 1 status : connected
remote-terminal-unit 1 association : guest
remote-terminal-unit 1 tx-mcs : 8
remote-terminal-unit 1 rssi : -52
remote-terminal-unit 1 signal-quality : 95
remote-terminal-unit 1 tx-rate-limiter : up-to-license
remote-terminal-unit 1 rem-tx-rate-limiter : 300
remote-terminal-unit 1 connect-time : 0000:01:32:46
• Eth-port – name of the RF port that is used to connect to the TU.
• Mac – MAC address of the remote TU.
• Name – text string. Set the name of the remote TU. Default: S/N of the remote
TU.
• Status (R/O) – connection status: connected (in case of association to a BU) or
scanning (if not associated to a BU).
• Association – guest or managed.
o Guest – TUs that are connected as ‘guest’ do not require setting on
the BU side. An RF port will be created in case TU is connected.
No services configuration is supported for ‘guest’ TUs (transparent
bridge only).
o Managed – TUs that are set to ‘managed’ reserve their RF port
settings and will allow settings of services.
Note:
TUs connected as ‘guests’ will be displayed only in case they are connected.
TUs connected as ‘managed’ will be displayed even if they are down.
• Tx-mcs – the Adaptive Modulation & Coding Scheme (A-MCS) which is used to
transmit the packets. MCS values: 1 to 8 (MCS 10 for very short links). MCS 0 is
used to carry control messages only (no data traffic).
• RSSI – Receive Signal Strength Indication (in dBm). Available as long as the TU is
connected.
• Signal-quality – the signal’s quality indication. Values: 0 to 100.
• Tx Rate Limiter – User may set rate limiter to limit the data rate on the radio
from BU towards the TU. Value in Mbps. Default is ‘up-to-TU-license’, meaning
the rate limiter will be set to the value of the TU configured capacity license
(Data Rate set on System->Maintenance->Licensing page).
• Rem-Tx-Rate-Limiter (R/O) – the value of the Tx rate limiter at the remote TU.
• Connect-time – time the TU is connected to the BU since last disconnection.