Operation and Maintenance Manual

MultiHaul™ Installation, Operation and Maintenance Manual
Page 74
Rollback is a safety measure that allows recovering from system configuration changes
that caused loss of communication.
When Rollback is used, a timer runs (and restarts) whenever command is entered. If no
command is entered within the timeout period, the system automatically reboots and
comes up with the saved startup configuration.
A Rollback timeout is especially recommended when configuring remote elements that
are being managed over the link.
To specify the Rollback timeout period, use the following command:
set rollback timeout <duration-in-seconds>
4.3 Configuring and Displaying System Information Using the CLI
Use the show system command to display basic information about the ODU.
Local_Site>show system
MH-B100-CCS-PoE-MWB>show system
system description : MH-B100-CCS-PoE-MWB
system snmpid : .1.3.6.1.4.1.31926
system uptime : 0000:01:17:44
system contact : undefined
system name : MH-B100-CCS-PoE-MWB
system location : ""
system voltage : 45 poe
system temperature : 36
system date : 2017.12.06
system time : 11:40:12
system cli-timeout : 15
system loop-permission : enabled
system terminal-units-isolation : disable
system eth-ports-isolation : disable
system unit-mode : normal
system remote-config : disable
system leds-turn-off : never
Description model description (R/O).
SnmpID SNMP ID for Siklu products (R/O).
Uptime R/O field. Time elapsed from last power on.
Contact text string.
Name text string. Enter a unique name to identify your system.