Operation and Maintenance Manual
MultiHaul™ Installation, Operation and Maintenance Manual
Page 23
The compact MultiHaul™ T201 has a mounting bracket as part of its body. Use two cable
ties to fix it to the pole.
2.6 Connecting the Cables – MultiHaul™ B100/T200
1. Electrical Ground Point (GND)
2. Ethernet RJ45 Eth#1 (PoE in)
3. Ethernet RJ45 Eth#2 (PoE Out) – model dependent
4. Ethernet Eth#3 or RJ45 (PoE Out) – model dependent
5. Reboot push-button. Restore Factory Default (push for
more than 10 seconds)
Figure 2-3 MultiHaul™ B100/T200 Connection Panel Details
Caution:
Use only Class 1 Laser SFP with rated voltage of 3.3Vdc which is safety approved to
UL/EN/IEC 60950-1 and which is CDRH registered.
2.6.1 Power Options
To power up the MultiHaul™ using PoE, connect the cable to Eth#1.
You may use direct DC (input range: 36÷57Vdc) by using an RJ45-DC Adapter (can be
obtained from Siklu). In this case, port ETH#1 will be used for power only.
Caution:
Use a PoE power supply which is safety approved to UL/EN/IEC 60950-1 as a limited
power source (LPS) with rated voltage of 42-57Vdc and rated current of 1.4A max,
and approved for the altitude where it is deployed