Plume Displacement
Kit Extension & Clip
Solo HE A
Flue options
Plume Displacement Kits 70/110mm diameter - Mulitt Flue Group L
Part No. 5121371
Plume Displacement
Terminal Kit inc Elbow
& Clips.
Part No. 5121374
Plume Displacement
Kit Bend - Pair
Part No. 5121373
Plume Displacement
Kit Bend
IMPORTANT:
If tting a Plume Displacement Flue Kit, the air inlet must be a minimum
of 150mm from any opening windows or doors.
The inlet of the PDK MUST be at least 300mm above ground or
balcony level or any projection or ledge. A guard must be tted where
the inlet is below 2 metres.
500mm Min.
For Plume Displacement Kit permissible ue lengths please see page 13.