Technical information
36
Technical Helpline: 0844 871 1525
Megao System Compact GA
Heat Input CH (Net)
Max Min
12 model kW 12 2.1
15 model kW 15 2.2
18 model kW 18 2.6
24 model kW 24 3.5
28 model kW 28 4.1
NATURAL GAS ONLY !
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
12 model m
3
/h 1.27
15 model m
3
/h 1.59
18 model m
3
/h 1.90
24 model m
3
/h 2.54
28 model m
3
/h 2.96
Inlet Pressure (Natural Gas - G20)
mbar 20
PROPANE ONLY !
Max Gas Rate
(Propane - G31)
(After 10 mins)
12 model kg/h 0.93
15 model kg/h 1.17
18 model kg/h 1.4
24 model kg/h 1.86
28 model kg/h 2.18
Inlet Pressure (Natural Gas - G31)
mbar 37
Power Consumption
12 model W 110
15 model W 108
18 model W 125
24 model W 104
28 model W 135
Flue Terminal
Diameter 100mm
Dimensions
Projection 125mm
Connections
copper tails
Gas Inlet 22mm
Heating Flow 22mm
Heating Return 22mm
Pressure Relief Discharge 15mm
Appliance Type
C
13
C
33
C
43
C
53
Appliance Category
CAT I
2H 3P
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an earthed supply)
Electrical Protection
IPX5D
Internal Fuse Rating
F2L
Condensate Drain
To accept 21.5mm (3/4 in) plastic waste pipe
External Fuse Rating
3A
Heat Output CH (Condensing)
Max Min
12 model kW 12.7 2.2
15 model kW 15.9 2.3
18 model kW 19 2.8
24 model kW 25.4 3.7
28 model kW 29.6 4.3
Heat Output CH (Non-Condensing)
(Net) Max Min
12 model kW 12 2
15 model kW 15 2.1
18 model kW 18 2.5
24 model kW 24 3.4
28 model kW 28 4
Injector
12 model mm 3
15 model mm 3.3
18 model mm 3.6
24 model mm 4.6
28 model mm 4.9
NOTE: All data in this section are nominal values and subject to normal production tolerances.
Technical data (12, 15, 18, 24, 28)
MX8013 - Technical pocket guide DL v14_post proof.indd 36 30/08/2012 14:29