Datasheet

MSDS-No.: 175676
V007.0
X32-10i LIQUID FLUX
Page 5 of 12
Derived No-Effect Level (DNEL):
Name on list
Application
Area
Route of
Exposure
Health Effect
Exposure
Time
Value
Remarks
Propan-2-ol
67-63-0
Workers
Dermal
Long term
exposure -
systemic effects
888 mg/kg bw/day
Propan-2-ol
67-63-0
Workers
Inhalation
Long term
exposure -
systemic effects
500 mg/m3
Propan-2-ol
67-63-0
general
population
Dermal
Long term
exposure -
systemic effects
319 mg/kg bw/day
Propan-2-ol
67-63-0
general
population
Inhalation
Long term
exposure -
systemic effects
89 mg/m3
Propan-2-ol
67-63-0
general
population
oral
Long term
exposure -
systemic effects
26 mg/kg bw/day
Adipic acid
124-04-9
general
population
oral
Acute/short term
exposure -
systemic effects
19 mg/kg bw/day
Adipic acid
124-04-9
general
population
Dermal
Long term
exposure -
systemic effects
19 mg/kg bw/day
Adipic acid
124-04-9
general
population
oral
Long term
exposure -
systemic effects
19 mg/kg bw/day
Adipic acid
124-04-9
general
population
Inhalation
Long term
exposure -
systemic effects
65 mg/m3
Adipic acid
124-04-9
Workers
Dermal
Acute/short term
exposure -
systemic effects
38 mg/kg bw/day
Adipic acid
124-04-9
Workers
Inhalation
Acute/short term
exposure -
systemic effects
264 mg/m3
Adipic acid
124-04-9
Workers
Inhalation
Acute/short term
exposure - local
effects
5 mg/m3
Adipic acid
124-04-9
Workers
Dermal
Long term
exposure -
systemic effects
38 mg/kg bw/day
Adipic acid
124-04-9
Workers
Inhalation
Long term
exposure -
systemic effects
264 mg/m3
Adipic acid
124-04-9
Workers
Inhalation
Long term
exposure - local
effects
5 mg/m3
Adipic acid
124-04-9
general
population
Dermal
Acute/short term
exposure -
systemic effects
19 mg/kg bw/day
Adipic acid
124-04-9
general
population
Inhalation
Acute/short term
exposure -
systemic effects
65 mg/m3
Biological Exposure Indices:
8.2. Exposure controls:
Engineering controls:
Ensure adequate ventilation, especially in confined areas.
Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.
Extraction is necessary to remove fumes evolved during reflow.