Specifications
56 MultiModemISI Hybrid Series, ISIHI-2S/2U
Chapter 3—Software/Driver Installation
Error Messages
1. *Error: An ISIHI-2S/2U does not seem to appear at address X*
The driver could not find the ISI residing at the address X. Make sure there is no other
device in your system at the same I/O address and that the ISI is seated properly in the
system slot.
2. *Error: ISIHI-2S/2U rejected the load header*
*Error: ISIHI-2S/2U got out of sync*
*Error: ISIHI-2S/2U verify failed at address X*
*Error: Expected X received Y*
*Error: Verify got out of sync*
The file server is not able to communicate with the ISIHI-2S/2U. Make sure no other
device is residing in the system at the same I/O address you chose for the ISIHI-2S/
2U. Power down the server and make sure the ISIHI-2S/2U is seated properly in the
system slot. Power up the file server and try to load the AIO driver again. If the
problem persists, contact the Multi-Tech Technical Support team.
Troubleshooting
Problem: I loaded the driver at the file server console, then I started NetWare Connect
and connected a modem to a port on an ISIHI-2S/2U. When I try to communicate with the
modem, I see the DTR of the modem being raised, but the modem does not respond to
my AT commands.
Solution: There might be an IRQ conflict between an ISIHI-2S/2U and some other
hardware in your system. Even though that particular device (for example, a mouse) is not
activated under NetWare, that device will still control the IRQ. Refer to your systems
documentation to find out how to disable that device.
Configuring Ports for NetWare Connect
To set up NetWare Connect ports, enter LOAD NWCCON at the NetWare console
prompt. LOAD NWCCON opens the NetWare Connect Configuration Utility. Select the
appropriate menu options (modem type, speed, flow control, etc.)
Removing the Driver (Novell)
Remove file AIOISIX.NLM from the system directory and make the appropriate changes
to the Autoexec.ncf file.