- MultiConnect Adapter User Guide

Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 19
General Commands – Setup
Command Syntax set login
Description
Prompts the Login for the command shell when enabled, and doesn't when
disabled.
Default Value
Enable
Success
OK
Error 1. Too few arguments
"Usage: set login <enable/disable>
Type 'set login ?' for more information"
2. Invalid string
"error: set login <enable/disable>"
Command Syntax set login auto-dialout-login <enable/disable>
Description
Enables/Disables authentication for Telnet auto-dialout.
Default Value
Disable
Success
OK
Error 1. Too few arguments
"Usage: set login auto-dialout-login <enable/disable>
Type 'set login auto-dialout-login ?' for more information"
2. Invalid string
"error: set login auto-dialout-login <enable/disable>"
Command Syntax set time <HH:MM:SS>
Description
Sets the system time.
Default Value
00:00:00
Success
OK
Error 1. Too few arguments
Usage: set date HH:MM:SS
Type 'set date ?' for more information
Error: Time in HH:MM:SS format
Too few arguments. Possible argument(s) are
ip login
serial date
ppp time
Command Syntax set watchdog <enable/disable>
Description
Enables/Disables the watchdog timer.
The timer value is set to 6.5 seconds. This is the upper threshold value.
Note: Watchdog timer comes into effect only after reboot. Hence,
invoking this command calls for a reboot on save.
Default Value
Enable
Success
OK
Error 1. Too few arguments
"Usage: set watchdog <enable/disable>
Type 'set watchdog <enable/disable> ?' for more information"
2. Invalid string
"error: set watchdog <enable/disable>"