Register Unit Range Default Description
S40 104 (68h) General Bit-Mapped Options Status. Indicates the status of
command options.
Default: 104 (68h) (01101000b)
Bits 0-1 MNP Extended Services (-Kn)
0 = Disable extended services (-K0) (Default.)
1 = Enable extended services (-K1)
2 = Enable extended services (-K2)
Bit 2 Reserved
Bits 3-5 Break Handling (\Kn)
0 = \K0
1 = \K1
2 = \K2
3 = \K3
4 = \K4
5 = \K5 (Default.)
Bits 6-7 Reserved*