User Guide Controller MR9600
MR9600 User Guide
36 CommPlete Communications Server
e1cfg
Parameter: Device
Description: Sends E1 configuration information stored in nonvolatile memory to the specified device.
The specified device must be an E1 device. E1 devices can exist only at 1b, 1c, 5b, 5c, 9b, 9c, 13b, and 13c.
Security: Operator
Example:
[0] A:\MMM # e1cfg 13b
e1channelstatus, e1chstatus
Parameter: Device
Description: Displays the status of all the channels for the given E1 device.
Security: Guest
Example:
[0] A:\MMM # e1chstatus 13b
Channel CO Modem OOS Channel CO Modem OOS
1 On Hook On Hook 2 On Hook On Hook
3 On Hook On Hook 4 On Hook On Hook
5 On Hook On Hook 6 On Hook On Hook
7 On Hook On Hook 8 On Hook Timeout
9 On Hook On Hook 10 On Hook On Hook
11 On Hook On Hook 12 On Hook On Hook
13 On Hook On Hook 14 On Hook On Hook
15 On Hook On Hook 16 On Hook On Hook
17 On Hook On Hook 18 On Hook On Hook
19 On Hook On Hook 20 On Hook On Hook
21 On Hook On Hook 22 On Hook On Hook
23 On Hook On Hook 24 On Hook On Hook
25 On Hook On Hook 26 On Hook On Hook
27 On Hook On Hook 28 On Hook On Hook
29 On Hook On Hook 30 On Hook On Hook
CO - Central Office, * - Inconsistent State
e1setup
Parameter: Device
Description: Sets the E1 configuration information associated with an E1 device. This information is
stored in a nonvolatile area of memory so that the device can be properly reconfigured on power-up or
reset. The specified device must be an E1 device. E1 devices can exist only at 1b, 1c, 5b, 5c, 9b, 9c, 13b, and
13c.
Security: Supervisor
Example:
[0] A:\MMM # e1setup 13b
Use settings from:
1. Use Active Settings (pre-configured card)
2. Use System Defaults (new card)
3. Use Stored Settings (swapping cards)
Enter Selection (q(uit), <1>): 1
Getting E1 Card Info ...
1. Channel Polling Interval (Sec):20
2. Error Threshold :10
3. Disconnect Timeout (sec) :11