CAUTION: Do not connect 50Hz or 3 -phase loads to the generator .
120V/20A AC Duplex
Receptacles
240/120VAC
Receptacle
(L14-30)
Figure 16- Receptacles available on the generator
CIRCUIT BREAKER
The circuit breakers help to prevent the generator fro m electrical overload. If your receptacle short
circuits or becomes overloaded by an electrical device or devices with too great a wattage rating, the
circuit protector may shut off power to the receptacle. If this happens, you will see the voltage meter
changing from having voltage output to no voltage. and you will not be able to draw power from the
overloaded receptacle. In the event of such an overload, disconnect all electrical devices from the
generator and press the circuit breaker to “ON” position. If power still does not return to the receptacle,
call our customer service line.
ATUOMATIC IDLE REDUCTION
When load≥100W(0.83A), the generator will run from automatic idle reduction state to normal
running state. The transition will be finished within 20 seconds.
When load ≤60W(0.5A), the generator may run from normal running state to automatic idle reduction
state. The transition will be finished within 30 seconds.
SOME NOTES ABOUT POWER CORDS
Long or thin cords can drain the power provided to an electrical device by the generator. When using
such cords, allow for a slightly higher rated wattage requirement by the electrical device. See Figure
17 for recommended cords based on the power requirement of the electrical device.