Installation manual
69
STOP
Caution
Thermo King Multi-Temp host units are shipped with a 35 kPa (5 psi) holding charge of R-404A. This holding
charge of approximately 1 kg (2 lbs.) of refrigerant must be recovered.
SEVERE COMPRESSOR DAMAGE will result from operating the engine before completing the system
installation which includes: installing the components, recovering the host unit holding charge, releasing the
remote unit holding nitrogen charge, soldering the refrigeration lines, leak testing the system, evacuation and
clean-up, and charging the system. (SEE INSTALLATION MANUAL-B)
Recover Refrigerant
At Thermo King, we recognize the need to preserve the environment and limit the potential harm to the ozone
layer that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the
atmosphere.