Installation manual
62
Connecting the CargoWatchâ„¢ Sensors (Option)
NOTE: ONLY CargoWatch Sensors Can Be Used
CONNECTING SENSORS
NOTE: The sensor are not polarity sensitive.
1. Locate the CargoWatch Sensor Harness behind the evaporator access
panel.
2. Unplug the connector from the harness.
3. Removes orange end from connector.
4. Remove only the plugs from the connector holes for the sensors you are
connecting. Unused holes must remain plugged.
5. Insert WHITE pin connector and wire into correct connection until it
locks into position (Detail I). The wire side of the connector is shown.
6. Insert BLACK pin connector and wire into correct connection until it
locks into position (Detail I). The wire side of the connector is shown.
Reinstall orange end (3) back onto connector (2), apply a light coating
of Superlube to electrical connections and plug sensor back into mating
connector on the Sensor Harness (1).
7. Connect the CargoWatch Sensor Harness to the sensor using the splice
connectors. Crimp splice connectors securely and apply heat with a
heat gun. NOTE: The CargoWatch Sensor wires are not polarity
sensitive.
8. Secure sensor with appropriate clamps.
SENSOR PLUGS
1 #1 and #12
2 #2 and #11
3 #3 and #10
4 #4 and #9
5 #5 and #8
6 #6 and #7
SENSOR PLUGS
1 White into #1
2 White into #2
3 White into #3
4 White into #4
5 White into #5
6 White into #6
SENSOR PLUGS
1 Black into #12
2 Black into #11
3 Black into #10
4 Black into #9
5 Black into #8
6 Black into #7