Installing the Status Light (Option)
Installation
NOTE: Surface mounted status light installation shown, flush
mounted light installs into recessed opening (see “Flush Mounted
Status Light Opening Dimensions (Option)” on page 21) and
electrical connections are made the same.
1. Mount the Status Light in a location so that is visible in the tractor
mirror to the driver.
Mark and drill the four mounting holes using a 3/16'' drill.
Mount the status light in position with the supplied rivets.
2. Route harness as shown allowing a “drip-loop” to prevent water from
migrating into the Status Light.
3. Secure harness to the bracket and trailer using the supplied clamps and
rivets.
4. Connecting the Status Light harness:
STANDARD DISPLAY - connect harness to the matching 6-pin
connector located outside the unit behind the battery tray and to the left
of the control box.
Secure any excess harness with tie bands to the main harness
behind the battery tray.
FUEL COMBO and TRIPLE COMBO DISPLAYS - route the
harness through the harness grommet and into the control box.
Connect the 4-pin connector to the Remote Light port on the circuit
board.
Connect the 8-pin connector to CAN1 (J12). If this position is
occupied use CAN2 (J13) or CAN3 (J14).
NOTE: If all CAN ports are occupied use the CAN extender Harness
available from your Thermo King Dealer.
Be sure the connectors are locked securely in place on the circuit
board.
Secure any excess harness with tie bands to the main harness
behind the battery tray.
IMPORTANT: DO NOT secure excess harness to battery cables or
refrigeration lines.