Installation manual
12
Mounting Hardware Requirements
Mounting Bolts
NOTE: The location of the unit mounting bolts in the trailer front wall
is critical to proper unit installation.
All mounting bolts must be square with the front wall and securely
fastened to the trailer wall in such a manner to allow the mounting nuts be
torqued to 82 N•m (60 ft. lbs.) from outside the trailer.
• Mounting bolts are to extend a minimum 57.20 mm (2.25 in.) and a
maximum of 63.50 mm (2.50 in.) beyond the front wall.
• Surface of all mounting bolts are to be flat within 2.50 mm
(0.10 in.).
Mounting Bolt Specifications
Use Metric M12 x 1.75 pitch class 8.8 (1/2 in.-13 UNC - 28 Rolled thread
grade 5), medium carbon steel bolts and locking nuts. All hardware must
be zinc plated with dichromate finish.
DANGER: Eight mounting bolts must be installed to properly
secure the unit to the trailer front wall! Failure to do so could
result in severe damage to equipment, void the warranty or
cause personal injury or death!
DANGER: The use of mounting bolts other than those
specified could result in severe damage to equipment, void