2 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
MULTILINK MC-E10 & MC-E100 CONVERTER SWITCH
100BASE-FX, half-duplex (single-mode): .....................................412 m (1350 ft)
100BASE-FX, full-duplex (single-mode):.......................................20.0 km (65,620 ft)
100BASE-FX, full-duplex (single-mode, long reach):..............40.0 km (131,240 ft)
OPERATING ENVIRONMENT- AMBIENT TEMPERATURE
Multilink MC-E10, Multilink MC-E100:............................................32ºF to 104ºF (0ºC to 40ºC)
Long term per independent agency tests (UL):........................-40ºF to 149ºF (-40ºC to 85ºC)
Short term per IEC Type tests:..........................................................-40ºF to 167ºF (-40ºC to 75ºC)
Storage Temperature, All models - Cold Start:.........................to -40ºC
Ambient Relative Humidity: ..............................................................5% to 95% (non-condensing)
Altitude (All models): .............................................................................-200 to 50,000ft. (-60 – 15,000 m)
Conformal Coating (optional) for Humidity protection
Note
These models are designed for NEBS compliance, including, vibration, shock and altitude.
PACKAGING
Enclosure: ................................................................................................Rugged sheet metal (Steel)
Dimensions, Switch unit: ....................................................................Height x Width x Depth
3.5 in H x 3.0 in W x 1.0 in D
(8.9 cm x 7.6 cm x 2.5 cm)
Weight - all models: .............................................................................8 oz. (227g)
Power supply weight: ...........................................................................7.9 oz (225g)
COOLING METHOD
Convection, plus the case is used as a heat sink.
POWER SUPPLY
AC Power Supply (using an external power adapter):
All models have a (8 to 15) V DC output with 6ft long cord and a 2.5mm center +ve jack. The
power supplies are temperature rated to match the Converter Switch ratings.
Temperature un-controlled Ratings (-40 to 75°C):..................Outdoor temperature rated.
Input: IEC 320 connector on the 100
to 240 V AC 47 to 63 Hz external
power adapter. Requires a user
supplied power cord.
Output: 12 V DC, 2 A
Direct DC Power Supply:
Built-in terminal block for +, -, ground along with 12 V DC jack
12 V DC internal (range of 8.0 to 15 V DC).
24 V DC internal (range of 18 to 36 V DC).
-48 V DC internal (range of 36 to 60 V DC), -, ground