Installation Instructions

TECHNICAL MANUAL TS 3x.10 KNX ENGLISH
12
Number Name Object function C R
W T U Objekt size Data type
125
E3 Store scene
input
C
-
W
-
-
1 Bit
enable
125 E3 Enable save input C - W - - 1 Bit enable
125 E3 switching level 5 output C - - T - 1 Bit switching
125 E3 Switching long actuation output C - - T - 1 Bit switching
126 E3 Level up/down switching input C - W - - 1 Bit switching
126 E3 ZZ: Limit value exceeded output C - - T - 1 Bit Boolean
127 E3 Number actuations input C - W - - 1 Byte counter pulses (0...255)
127 E3 ZZ: Counter reading request input C - W - - 1 Bit switching
128 E3 ZZ: Reverse direction input C - W - - 1 Bit Boolean
129 E3 ZZ: reset input C - W - - 1 Bit Boolean
130 E3 ZZ: Stop input C - W - - 1 Bit Boolean
139 E3 Disable input C - W - - 1 Bit enable
141 E4 switching sensor output C - - T - 1 Bit switching
141 E4 Alarm sensor output C - - T - 1 Bit 1-Bit, Alarm
141 E4 switching output C - - T - 1 Bit switching
141 E4 Blinds UP/DOWN output C - - T - 1 Bit up/down
141 E4 Switch (event 0) output C - - T - 1 Bit switching
141 E4 Priority (event 0) output C - - T - 2 Bit priority switching
141 E4 1-Byte value (-128...127) (Event 0) output C - - T - 1 Byte 8-Bit unsigned value, counter pulses (0...255)
141 E4 1-Byte value (0...255) (Event 0) output C - - T - 1 Byte counter pulses (0...255)
141
E4 Scene (Event 0)
output
C
-
-
T
-
1 Byte
scene control
141 E4 2-Byte value (-32.768...32.767) (Event 0) output C - - T - 2 Bytes 2-Byte signed value, pulses difference
141 E4 2-Byte value (0...65.535) (Event 0) output C - - T - 2 Bytes 2-Byte unsigned value, pulse
141
E4 4-Byte value (-2.147.483.648...2.147.483.647) (Event 0)
output
C
-
-
T
-
4 Bytes
4-Byte signed value, counter pulses
141 E4 4-Byte value (0...4.294.967.295) (Event 0) output C - - T - 4 Bytes 4-Byte unsigned value, counter pulses
141 E4 2-Byte Floating point (Event 0) output C - - T - 2 Bytes float value, Temperature (°C)
141 E4 Scene output C - - T - 1 Byte scene control
141 E4 switching level 1 output C - - T - 1 Bit switching
141 E4 switching 1 actuation output C - - T - 1 Bit switching
141 E4 HZ: Counter reading 1-Byte-value output C - - T - 1 Byte 8-Bit unsigned value, counter pulses (0...255)
141 E4 HZ: Counter reading 1-Byte-value output C - - T - 1 Byte counter pulses (0...255)
141 E4 HZ: Counter reading 2-Byte-value output C - - T - 2 Bytes 2-Byte signed value, pulses difference
141 E4 HZ: Counter reading 2-Byte-value output C - - T - 2 Bytes 2-Byte unsigned value, pulse
141 E4 HZ: Counter reading 4-Byte-value output C - - T - 4 Bytes 4-Byte signed value, counter pulses
141 E4 Output value output C - - T - 2 Bytes float value, Temperature (°C)