Datasheet
75
Rights to technical amendments reserved.
Elapsed time counters BW 30 · BG 30
for panel mounting · Alternating/Direct Current
Technical data BW 30.18 BG 30.18
Alternating current Direct current
Supply voltages 230 V, 50 Hz (standard) 12–48 VDC
(Please state when ordering) or 115 V, 50 Hz
or 24 V, 50 Hz
Special voltages – 5–24 V, 36–120 VDC,
100–300 VDC
Other voltages on request on request
Special frequency 60 Hz –
Voltage tolerance ±15% ±10%
Power consumption (real power) 0.11 W approx. 20 mW at 12 VDC
Counter capacity 99999 h. 99999 h.
Accuracy of reading 0.01 h. 0.1 h.
Numeral height 4.4 mm 4.4 mm
Numeral colour
white, decimal figures red white, decimal figures red
Operation indicator fast-running wheel LED
Permitted ambient temperature –15°…+50°C –10°…+50°C
Enclosure self-extinguishing thermoplastic
Type of connection Universal: Screw, soldered and
6.3 x 0.8 mm AMP plug-type connections
Type of protection (DIN EN 60529) Front IP 54 Front IP 54
Class of protection II (when fitted in accord- III (up to 48 VDC)
ance with regulations)
Accesso ri es
Retaining clip 715.005
쐍 Front panel 53 x 28 mm
쐍 Integral locking spring
쐍 With universal connections
쐍 Touch proof connections to VBG 4
쐍 Mounting aperture: 50 x 25 mm
BW 30.18
Order number Version
BW 30.18 Alternating current
BG 30.18 Direct current
Housing colour