Data Sheet
PRODUCTS
Page 2 / 2
MI.PUCK SYSTEM
müller EA 46.22 pro4 mi.puck switch
Technical data
Supply voltage 230 V, 50-60 Hz
Channels (potential of supply voltage) 2x outputs normally open (A, B)
Switching capacity
ohmic load
Time switch: 6 A at cosφ=1
Blind control: 2x 3 A bei cosφ=1
Thermostat: 4 A bei cosφ=1
Hygrostat: 6 A bei cosφ=1
Transmission type
Bluetooth 4.2
Range max. 75 m
Inputs
2x inputs 230 V~ (Input 1 / Input 2)
assignment:
Input 1 = A / UP
Input 2 = B / DOWN
Input function
push-button / switch
Blind control: movement command / stop
Time switch: change ON / OFF or timer
Time base Quartz
Quartz accuracy
(at 20 °C)
≤ ±0,5 Sec./day
(Quartz accuracy optimized for typical
ambient conditions)
Power back-up (at 20 °C)
approx. 10 years (depends on the Lithium-
battery life)
Permitted ambient temperature -30... +45 °C
Housing self-extinguishing thermoplastic
Dimensions 41,4 x 44 x 20 mm
Mounting
Flush-mounting (preferrably combined with
hollow-wall box)
Type of connection Screw terminals
Type of protection IP 20 to DIN EN 60529
Class of protection II when installed according to regulations
Mode of operation
(DIN EN 60730-1)
(DIN EN 60730-2-7)
1 BSTU
Degree of contamination
(DIN EN 60730-1)
2
Rated surge voltage
(DIN EN 60730-1)
4 kV
Minimum requirement
Android Version 4.4
iOS 11.0
Bluetooth 4.2
Accessory
(free download)
Programmable and controllable with
smartphone via Bluetooth:
App - Save`n Carry
Rights to technical amendments reserved / Technische Änderungen vorbehalten
Droits de modifications techniques réservés / Suscettibile di errori e modifiche
Hugo Müller Gmbh & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen