User's Manual

ENTR Project
Jan, 01, 2017
An ASSA ABLOY Group Brand
Page 9
Figure 5-Lock Transaction Message structure
Lock
7A506176656c6f636b00(ASCII)
The 506176656c6f636b00 is the lock name that you receive from the 0x72 message.
After sending the lock command you will receive an FE(acknowledge) or FF(Non acknowledge)
response.
3.3.8 In response you receive a 0x70 Status (see paragraph 4.2)
The status register contain the door status: Door is closed, Lock is locked, Muted,
Automatic locking, Charging and battery condition.
3.3.9 Get Status 0x7C(see table on paragraph 4.2)
Figure 5-Lock Transaction Message structure
Lock
7C506176656c6f636b00(ASCII)
The status register(0x70) contain the door status: Door is closed, Lock is locked, Muted,
Automatic locking, Charging and battery condition.
After sending the status command you will receive an FE(acknowledge) or FF(Non
acknowledge after timeout) response.
Dongle/UART
7A506176656c6f636b00
Dongle/UART
7C506176656c6f636b00