User guide

877-2-MUELLER
G-4
VENT INSTALLATION
Roof Ventilators (Optional)
1. Ventilators may be installed on the roof ridge after the roof sheets are on and before the
ridge roll or peak sheet is installed. The ventilators are ten feet long and usually are installed
at the peak and between two rafters.
2. Cut out the ridge roll or peak sheet to fi t the opening of the ventilator. Ensure that the
opening is cut correctly so the ventilator will fi t properly and provide enough lap over the
opening to prevent leaks. (The roof sheets may need to be trimmed to maximize venting).
3. Place the ventilator over the opening. Use molded rubber outside sealers to fi ll the gaps
between the ventilator fl ange and the roof sheets.
4. Attach the ventilator to the roof sheets with lap tek screws. Screw through the vent skirt to
the tops of the roof sheet ribs.
5. Locate the vent adjusting pull chains as desired. (According to vents instructions).