User guide

877-2-MUELLER
E-8
FASTENER INSTALLATION
Correct fastener installation is one of the most critical steps when installing roof panels. Drive
the fastener in until it is tight and the washer is firmly seated. Do not overdrive fasteners: A slight
extrusion of neoprene around the washer is a good visual tightness check.
Always use the proper tool to install fasteners. A fastener driver (screw gun) with and RPM of
1700-2500 should be used for self-drilling screws. Discard worn sockets, these can cause the
fastener to wobble during installation.
Sealant Tape
Proper sealant tape application is critical to the weather tightness of a building. Sealant tape
should not be stretched when installed. Apply only to clean, dry surfaces. Keep only enough
sealant tape on the roof that can be installed in a day. During warm weather, store sealant tape
in a cool dry place. During cold weather (below 60 degrees) sealant tape must be kept warm (60
degrees – 90 degrees) until application. After sealant tape has been applied, keep protective paper
in place until panel is ready to be installed.
Correct degree of
tightness. Note slight
circle of sealant
Too tight! Sealant
squeezed too thin.
Extrudes far beyond
fastener head
Too loose!
Sealant is not
compressed to
form seal
Lap Tek Screw
(20" O.C.)
Sealant Tape
Roof Panel
Roof Panel
Prevailing Wind Direction
Panel Rib
1
/4˝ Clearance Hole
NOTE: Always remove metal shavings from surface of panels at the end of each
work period. Rusting shavings can destroy the paint finish and void any warranty.