INSTALLATION OF WALL PANELS
Adjoining panels are installed with the overlapping rib toward the last erected panel. Position panel
to structural making sure that it is kept plumb and install fasteners at lapped rib. Check for proper
coverage (3' center to center) and correct as necessary. Install remaining fasteners.
Wood
Blocking
Blanket
Insulation
Wall
Panel
Wall Panel
Steel Frame Line
Sheeting
Direction
NOTE: Start first panel with major rib centered with endwall frame.