SCREW ALIGNMENT
Good alignment of the screws, especially on the wall panels, will give a professional appearance to
the wall panel installation. One way this can be accomplished is by pre-drilling holes in the panels
at identical locations. Up to 15 panels can be stacked together and drilled using a template panel.
Use 1/8” or 5/32” diameter drill bit for panel to structural fasteners and a 1/4” diameter bit for the
sidelap clearance holes. It is important to clean metal shavings off panel surfaces after
drilling to avoid rust stains.
Keep Ends
of Panels
Allinged
CLAMPING IS REQUIRED
Stacked Sheets
To Be Drilled
Pre-Drilled
Template
Sheet