Specification
1. Cut and fold back
plastic cover to reveal the
copper tube
2. Install solder ttings
in accordance with
manufacturer’s instruc-
tions and local codes
Note: If using a blowtorch, take
care to keep the ame away from
the plastic cover
3. When the joint is
complete and cool, replace
the plastic coat and wrap
the joint to give continuity
of protection
Note: Polyken #930 Tape Coating
for Joints & Fittings or comparable
alternative is recommended to
wrap the joint.
Type K Type L ACR Ref Coils
Nom. Size
O.D. Size Lengths Coils Lengths Coils Lengths Coils
1/4” 3/8” – 60, 100 ft – 60, 100 ft – 50, 100 ft
3/8” 1/2” – 60, 100 ft – 60, 100 ft – 50, 100 ft
1/2” 5/8” 10, 20 ft 60, 100 ft 10, 20 ft 60, 100 ft 20 ft 50, 100 ft
5/8” 3/4” 10, 20 ft 60, 100 ft 10, 20 ft 60, 100 ft 20 ft 50, 100 ft
3/4” 7/8” 10, 20 ft 60, 100 ft 10, 20 ft 60, 100 ft 20 ft 50, 100 ft
1” 1-1/8” 10, 20 ft 60, 100 ft 10, 20 ft 60, 100 ft 20 ft 50, 100 ft
1-1/4” 1-3/8” 10, 20 ft – 10, 20 ft – 20 ft 50, 100 ft
1-1/2” 1-5/8” 10, 20 ft – 10, 20 ft – 20 ft 50, 100 ft
2” 2-1/8” 10, 20 ft – 10, 20 ft – 20 ft 50, 100 ft
Installation
*Refrigeration coils available in 250 FT upon request. Items shown in blue are O.D. sizes
Specications
• Polyethylene coating made from low density
LDPE resin, is extruded at 0.025” minimum
wall and contains UV inhibitors
• Copper water tube (Types K & L) is
manufactured to meet the chemical and
mechanical properties of the applicable
ASTM B88 and ANSI/NSF 61 standards
• ACR and Refrigeration Service Coils are
manufactured to meet the chemical and
mechanical properties of the applicable
ASTM B280 standard
• OilShield meets NFPA 31 Standard for the
Installation of Oil-Burning Equipment and is
grooved to enhance leak detection
• GasShield meets NFPA 54 National Fuel
Gas Code
Grooved for
enhanced leak
protection.
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com • MLT-100
PLASTIC COATED TUBE