7.17 Raw Water Pump with Connections
7.17.1 Raw water pump – Relief bore check
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
Take special care when working on a running engine.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Checking relief bore on raw water
pump
1. Check relief bore for oil and raw water dis‐
charge.
2. Stop engine (→ Page 100) and disable en‐
gine start, observe general safety instruc‐
tions for maintenance and repair.
3. Clean the relief bore with a wire if it is dirty.
Permissible raw water discharge: up to
10 drops per hour;
Permissible oil discharge: up to 5 drops
per hour.
4. If discharge exceeds the specified limits:
Contact Service.