Operating instructions

7.4.2 Valve clearance – Check and adjustment
Preconditions
Engine is stopped and starting disabled.
Engine coolant temperature is max. 40 °C.
Valves are closed.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Feeler gauge
Y20010128 1
Torque wrench 10-60 Nm
F30510423 1
Torque wrench 60-320 Nm
F30047446 1
Ring socket wrench
F30039518 1
Preparatory steps
1. Remove cylinder head cover (→ Page 127).
2. Install barring device (→ Page 112).
3. Rotate crankshaft with barring device in en‐
gine direction of rotation until "OT-A1" mark
and pointer are aligned.
122 | Task Description | M015412/03E 2012-02
TIM-ID: 0000004352 - 004