Operating instructions

4.14 Stopping the engine from LOP
Preconditions
Engine is running in local mode.
CAUTION
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
Before shutting down, disengage gear and run the engine at idle speed for at least 10 mins. until
engine temperatures have dropped and constant values are displayed.
Stopping the engine from LOP
Item Action
LOP Disengage gearbox (→ Page 85).
LOP Operate engine at idle speed (→ Page 85).
Temperature indications Wait until engine temperatures do not fall any further.
LOP Press STOP button (→ Page 85).
STOP button is illuminated;
Engine at a standstill.
100 | Operation | M015412/03E 2012-02